OPERATION OF THE DEVICE
102
HYD 5K...20KTL-3PH
capacity can be discharged to a
minimum energy level of 2 kWh.
Discharge Depth
Max. Depth of Discharge (DOD) for
grid-connected mode. Standard
80%
EPS Discharge Depth
Depth of Discharge (DOD) for EPS
mode. Standard: 80%
EPS Safety Buffer
State of charge (SOC), where the
battery will be recharged in EPS
mode. Standard: 20%
Set force charge time
Define the time for the forced
charging
2. Battery Activation
Automatic activation
Enable / disable.
If Automatic activation is enabled,
the inverter will activate the battery
when the inverter need to discharge
or charge the battery according to
the operational mode settings.
If automatic activation is disabled,
the battery has to be activated
manually by s
election the “Manual
activation” menu item.
Manual activation
Select “Force activation” to activate
a battery from standby mode
Save
After adjusting, select “Save” menu
item to save the parameters.
3. Anti-reflux
(
Feed-in power limitation)
Activates or deactivates the feed-in
power function of the inverter and