TECHNICAL INTRUCTIONS- DISINFECTION CABINETS
Reproduction prohibited without the authorization of SOFINOR
FICHE TECHNIQUE
Cabinet with magnetic rail
Cabinet with basket rail
MODELS :
5 knives
414x150x646
15 knives
580x150x646
30 knives
1060x150x646
15 knives
414x150x646
25 knives
580x150x646
50 knives
1060x150x646
Model without key
MZ05
MZ10
MZ20
MZ05P
MZ10P
MZ20P
Model with key
MZ05S
MZ10S
MZ20S
MZ05SP
MZ10SP
MZ20SP
Made of stainless steel ( AISI 304L )
A transparent plexi-glass door with a magnetic closing or key lock
A timer ( 0 – 2 hours )
A germicide lamp 08 W (MZ05), 15 W (MZ10) or 30 W (MZ20) single phase
220-230V 50Hz (60Hz for United Kingdoms)
Sprinkle protection: IP24
Automatically stop if the door is open
INSTALLATION
1.1)
SETTING UP
- Wall fixing with 2 screws through the metal.
- Pierce two holes in the wall, countermarked with the cabinet and place in the holes
two pegs and screws without tightening.
- Hang up the cabinet on the 2 screws and make sure that it is in horizontal position
before tightening the screws.
1.2)
ELECTRICAL CONNECTION
The appliance must be supplied with the tension 220-230V single phase, 50Hz (60Hz for U.K)
Electrical connection which does not agree with the indicated tension “220-230V single
phase, 50Hz” (60Hz for U.K) cause the cancellation of the guarantee.
If the supply cable is damaged, it must be replaced by the special supply cable reference:
6570 MZ 3075 (6570 MZ 3100ANG for U.K) available in the factory or in the after-sales service.
USE
Connect the disinfection cabinet to the network 220-230V single phase according to indications.
Place the knives on the magnetic bar or in the basket carrier after their cleaning and drying.
Cabinet should be used carefully. The radiation UVC could cause physiological disorder.
Eyes and uncovered parts of the body should be kept away from the radiation of the
germicide lamp.
Close the glass door(s) because it is essential to protect the skin and the eyes from the ultraviolet
radiation, opened door can also disturb the disinfection of the knives.
Set the timer on 30 min. The bacterium are eliminated by the ultraviolet radiation.
After 30 min, the tube goes off automatically.
Return the knives on the magnet to disinfect the other side during 30 min.
It is not necessary to return the knives in case of cabinet with slides.
Set the timer on 30 min and wait for the automatically stop.
We recommend disinfecting the knives just before use.
If the knives are not used immediately, put them into an alcoholic solution to keep the disinfection
effect.