6.3
Testing Guide for Channel Testing
Channel (Ch) test is comprised of the connection from an active device (eg. Router) in a data rack, a
telecommunication outlet (horizontal cabling) and the connecting patch cords at both ends using
Channel test adapters at each end of the link under test. The recommended length for the patch cord
from the patch panel and the outlet is 5m.
1.
Insert the Channel adapters into the LOCAL and REMOTE units of the WireXpert.
2.
Power ON WireXpert. Check that WireXpert is in Copper testing mode.
3.
Set reference is required if the units are being paired for the first time. Refer to Chapter 2 on how to
set reference.
4.
Choose the Channel limits and configure other settings if necessary.
5.
Connect the LOCAL unit to the patch panel and REMOTE unit to the outlet using the patch cord
connected to be used.
6.
Press the AUTOTEST button to begin AUTOTEST.
Ch adapter
Ch adapter
Patch Panel
Horizontal Cabling
Outlet
Link under test
LOCAL
REMOTE