background image

11

Tyc

o C

ON

FID

EN

TIA

L

MODEL SWH-4

2

00 TECHNICAL 

SPECIFICATIONS

Cable Recommendations: 

4 core (minimum), shielded, 22 AWG 
(minimum) cable.

Connectors: 

12 position, 3.5 mm Screw Terminals - 
Plug-In

Certifications: 

FCC Part 15, CE and UL 294

Open Standards 
Compliance:

ISO 14443A
ISO 14443B (Depending on specific 
implementation)
ISO 15693 (including some partially 
compliant credentials)

Other Standards 
Compliance:

Deister SmartFrame® in both 125 kHz and 
13.56 MHz implementations 
HID® Prox at 125 kHz (All Formats)

Standard Color: 

Black (other colors available; contact your 
Software House representative)

Dimensions with backplate 
(height/width/depth): 

4.37" × 3.31" × 1.10" (110.99 × 84.07 × 
27.94 mm)

Power Supply 

8-16 VDC 125 mA maximum current @ 12 
VDC

Environments: 

Meets UL 294 standards for Outdoor Use.

Humidity: 

5 to 100% (non-condensing)

Operating Temperature: 

-31º F to 151º F (-35º to 67º C)

Summary of Contents for SWH-4200

Page 1: ...1 Tyco CONFIDENTIAL Model SWH 4200 Contactless Multi Technology 125 KHz and 13 56 MHz Reader Installation Guide Version A0 Part Number UM 090 January 2005...

Page 2: ...troduction 3 Features 4 Mounting 5 Installation Considerations 6 Wiring 8 Installation Notes 9 Troubleshooting 10 Model SWH 4200 Technical Specifications 11 FCC Digital Device Limitations 13 UL Standa...

Page 3: ...ammed sectors Refer to Table 1 for a complete list of compatible standards and data TABLE 1 Compatible Credential Formats Model SWH 4200 HID 26 Bit ISO 14443A MIFARE Sector HID Corporate 1000 ISO 1444...

Page 4: ...ials badges disk tags and key fobs Reads both 125 kHz and 13 56 MHz credentials in the same reader Electrical protection reverse polarity diode protection on power lines Data lines high speed transien...

Page 5: ...ng backplate with tamper magnet installed onto the wall FIGURE 1 Model SWH 4200 Reader Backplate includes tamper switch magnet NOTE Mounting holes fit standard U S single width electrical box and stan...

Page 6: ...onal isolation spacer INSTALLATION CONSIDERATIONS An isolation spacer available from Software House part number SWH ISOSPC may be used to improve the read range distance when mounting the reader to a...

Page 7: ...e distance between the two readers is less than four inches field interference between the two readers may result in a double badge read NOTE If two readers are being placed back to back on a wall les...

Page 8: ...critical for outdoor readers While the reader itself is designed and protected to IP65 standards the cable wires can potentially corrode and short together if not carefully mounted and tightly fasten...

Page 9: ...und line of the local power supply must be connected to the power supply of the controller The unit needs to be operated with a power source with limited power consumption according to EN 60950 1 2003...

Page 10: ...not open and the green LED does not light when a qualified credential is presented Verify that the door strike and the green LED are wired correctly Verify that the access credential has been entered...

Page 11: ...luding some partially compliant credentials Other Standards Compliance Deister SmartFrame in both 125 kHz and 13 56 MHz implementations HID Prox at 125 kHz All Formats Standard Color Black other color...

Page 12: ...cture of each individual credential Standard Wiegand Output including ID Pass Through Option Serial Number Read Fixed Wiegand bit stream option SmartFrame encrypted mifare Sector read and conversion t...

Page 13: ...in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense This device complies with Part 15 of the FCC Rules...

Page 14: ...sent appareil numerique n emet pas de bruits radioelectriques depassant les limites applicables aux appareils numeriques de la class A prescrites dans le Reglement sur le brouillage radioelectrique ed...

Page 15: ...ders Software House 70 Westview Street Lexington MA 02421 U S A In case of alteration of the product not agreed to by us this declaration will lose its validity SWH 4100 SWH 2100 SWH 1100 SWH 2000 SWH...

Page 16: ...Inc and is furnished to its customer solely to assist in the installation testing operation and maintenance of the equipment described This document may not be reproduced in whole or in part without t...

Reviews: