[27]
•
Check whether the switch is ON
•
Check the fuse and breaker
•
Check whether the ground cable is connected
Dirty welding face,
poor welding seam
•
Check whether shielding gas is provided
•
Check and set shielding gas flow
•
Check whether shielding gas is correct
•
Check whether polarity of welding torch is correct
Unstable welding
performance
•
Check whether Power source is correctly set to operate as per
mode selected
•
Check whether the welding torch is too hot or GAS flow not proper
•
Check whether the cables and ground cable are firmly connected
•
Check whether the setting parameters are correct
•
Check Tungsten rods selected is Proper
Fan Not working
•
Check the mains supply lead of Fan , make sure that the mains is
connected
•
Check Fan is JAM due to dust , clean it ,if still not OK replace it
Machine Showing Error
code
•
Check Code number and then rectify it as per problem mentioned in
code list
Welding current can
not be regulated
•
Check Potentiometer on torch is ok , also check its wiring
•
Check parameter is properly selected or locked
•
Check Potentiometer and its knob of the Power source
TIG flame not proper
and Tungsten rod s
burning
•
Check Argon Gas flow
Welding not proper and
spatter
•
Check whether the setting parameters are correct
•
Check the setting of arc force
•
Check the length of the cables
•
Check the type and flow rate of the shielding gas
•
Check whether welding cable is correctly connected
•
Check the filing metal
•
Check whether fault in 3 phase or low Input supply voltage