32
5.7 Status Bar
Ink
information
Ink status icons include:
Equipment
status
Hardware and software status in printer.
(e.g. Printing not started )
USB
information
Encoder
information
Photocell
information
Ethernet
information
1) Normal ( ): Normal ink status.
2) warning ( ): ink amount lower than 10%;
3) Error ( ): wrong cartridge, cartridge not installed, or ink used up.
When encoder is
connected, click ,
encoder signal test
interface appears.
When photocell is
connected, click ,
photocell signal test
interface appears.
The printer connection to computer is realized by
Ethernet port, therefore realizes equipment
operation and upgrade transmission on PC end.
Information includes display IP, mask code,
MAC, gateway.
Status includes: Unconnected (gray);
Normally connected (green, interaction with PC software normal);
Warning (yellow, interaction with PC software wrong, connection failure,
software on PC not activated, computer not switched on etc.).
Ink information includes dynamic and static information.
Static information includes cartridge serial number, client code,
cartridge type.
Dynamic information:
1) Ink volume, prospect print output for current data.
2) Ink used percentage, remainning prospect print output for current data.
Automatically displays by icon for equipment normally connected to USB port.
Support three devices: USB disk, mouse, and keyboard.
Status: not connected (gray), normal connection (green), warning (yellow).
Normally connected equipment will be displayed by icon USB disk,
mouse, or keyboard.
Displays encoder
or photocell
connection status
as unconnected
(gray) and
normally
connected
(green).
UV status
When UV LED is connected with printer, UV
status will displayed on the screen.
UV status including: type, serier number,
software version, hardware version, run time.