18. MISSING LINE MEASUREMENT
112
2. Sight the starting position, and press
[MEAS]
to
start measurement.
Press
[STOP]
to stop measurement.
$
• When measurement data already exists the
screen of step 3 is displayed and measurement
starts.
3. Sight the next target and press
[MLM]
to
begin observation. Slope distance, grade,
horizontal distance and height difference
between multiple points and the starting
position can be measured this way.
• Press
[MEAS]
to re-observe the starting
position. Sight the starting position and
press
[MEAS]
.
• When
[MOVE]
is pressed, the last target
measured becomes the new starting
position to perform missing line
measurement of the next target.
"18.2 Changing the Starting Point"
4. Press
{ESC}
or tap the cross in the top-right
corner to end missing line measurement.
Results for current point
Results for measurement between starting
position and second target