25
6. SETTINGS FOR THE SRX/NET
"Fine":
± 5" (approx.)
"Rapid":
± 30" to ± 10’ (depending on distance)
2. Set "Srch. method" to "R.C." in order to start
Turning operation in response to a Turning
command issued from the RC controller.
Set to "G.S." to search for the target in the area
specified in the Search area tab.
3. When neccessary, set the JOG dial turning speed
for vertical and horizontal rotation of the
telescope. The "Shift" point signifies the dial
turning speed at which telescope rotation
switches from the Lo speed setting to the Hi
speed setting.This Shift point, along with the Lo
and Hi speed settings can be configured
according to user preference.
Settings and Options
(*: factory settings)
(1) Lo
1 to 4 (3*) (steps. 4 is fastest)
(2)
Hi
1 to 4 (3*) (steps. 4 is fastest)
(3)
Shift point
1 to 4 (2*) (steps)
Press
[INIT]
to return JOG Setting tab settings
only to their factory settings.
4. Press
[OK]
.
The larger the number set
in (3) the further to the right
the Shift point is set