44
11. TROUBLESHOOTING
●
Pressing the POWER button
does not switch ON the power.
→
Check that the battery has been inserted.
Replace the battery.
C
"8.1 Using the Battery"
●
The RC controller switches OFF without warning.
→
Auto power-off function activated and the RC controller has not been operated for 30
minutes.
Deactivate this function if not needed.
C
"9.1 Setting Auto Power-off"
●
The total station does not perform Turning operation even when distance measure-
ment is executed.
→
The Turning operation setting of the total station is deactivated.
Set the "Srch method" setting for the SRX/NET to "R.C.".
C
"6.2 Settings for Auto Pointing and Auto Tracking"
Set the Search before Distance Measurement setting for the Series 230RM to "RC".
C
"7.4 Setup for Search Before Distance Measurement"
→
A connection has not been established with the total station.
Check that the communication settings for all connected devices are set to the same values.
Users with multiple RC controllers should make sure that the combinations of total stations, RC
controllers, and data collectors being used are correct.
C
"7.3 Communication Setup"
Check that the wireless modem cable is correctly connected. Check the remaining battery power.
●
Turning operation failure
→
The beam detector cover is closed.
Close the beam detector cover.
C
"7.1 Beam Detector"
→
Both the laser projection port and the prism are not pointing in the direction of the total station.
Point the laser projection port and the prism towards the total station.
→
The total station cannot receive the beam emitted from the RC controller as the amount of light is
too low.
Check that the Distance Mode setting is correct.
C
"8.2.2 Setting Distance Mode"
→
Turning operation has located the horizontal position but cannot find the vertical position.
Turning operation for the vertical position cannot be performed while the pole is tilted at an
angle.
Check that the pole is fixed in the correct position, vertically over the measurement point.
→
Check that there are no obstacles between the beam detector of the total station and the
laser projection port of the RC controller/prism.
→
Flat white surfaces in close proximity to the optical path between the total station beam
detector and RC controller laser projection port may reflect the emitted laser beam and
cause Turning operation failure. Have someone stand in front of such objects or otherwise
cover, such as with a dark-colored cloth.
→
There is dust or dirt on the beam detector/laser projection port.
Dust off minute particles with the lens brush before carefully wiping with the cleaning cloth.