49
13. SPECIFICATIONS
Whole System Specifications
Range:
(Slope distance between instrument and measuring point)
(Using Sokkia's reflective prism target during normal atmospheric
conditions
*1
)
Standard Mode:
2
*2
to 100m
*3
Far Mode:
2
*2
to 250m
*4
/300m
*3
Operating time
*5
:
About 15 sec. Up to finishing distance measurement (Rapid (single))
Operating range of function for automatically determining rotation direction:
Magnetic inclination is 80° or less and horizontal component is
more than 10µT
*6
Data collector:
Sokkia total station/3-D station-compatible product
*6
Control panel (keyboard)
3 Keys
Indicator
6 LED
Auto power-off
Yes (powers OFF if not used for 30 min.)/No
Audio tone
Yes
Operating temperature
-20 to 50°C
Storage temperature range
-30 to 70°C
Water resistance
IP55 (IEC 60529:2001)
Size
99 (L) X 124 (W) X 196 (H) mm
Weight
About 1.1 kg (with BDC46B)
*1:
Normal: Slight haze, visibility about 20 km, sunny periods, weak scintillation.
Depends on the wireless modem used.
*2:
Possible to use 1.8m (horizontal distance), height of instrument point and measurement point
is almost the same, instrument height is 1.5m, and prism height is 0.05m.
*3:
About 20m height difference between instrument and RC controller laser projection port.
*4:
About 40m height difference between instrument and RC controller laser projection port.
*5:
Time taken between the start of the search and the obtaining of distance measurement results
after the completion of Auto Pointing. Normal atmospheric conditions, instrument Turning
horizontally 90°, 100m distance between instrument and measuring point.
Depends on the conditions and wireless modem used.
*6:
For details, contact your Sokkia agent.
RC Controller (RC-PR3)
Laser Projection Port
Signal source
Laser diode (IEC60825-1 Amd. 2: 2001/FDA CDRH 21 CFR Part
1040.10 and 1040.11 (Complies with FDA performance standards for
laser products except for deviations pursuant to Laser Notice No.50,
dated July 26, 2001.))
Wavelength: 785nm
Beam projection area
Horizontal direction:
-10 to 10°
Angle of elevation:
More than 40°
Angle of depression:
More than 30°
Rotation direction detector
Direction detector
magnetic compass sensor (geomagnetic
measurement method)