4. ON-DEMAND REMOTE CONTROL FUNCTIONS
8
To perform Turning, follow the procedure below.
C
For measurement procedure, see "4.2 Measurement Flow"
1. Point the RC-Controller laser projection port
and prism in the direction of the total station
and instruct the instrument to start Turning. A
laser beam is emitted from the projection port.
At the same time, the
Bluetooth
unit (COM 1)
relays the instruction to begin Turning.
2. The total station begins to rotate horizontally,
searching for the emitted laser beam. If it is
not detected by the end of the second rotation,
an error occurs.
3. Once the position of the horizontal direction
has been determined, the total station
telescope then begins to rotate along the
vertical axis searching for the position of the
prism.
4. Once the position of the vertical direction has
been determined an audio sounds and the
total station automatically sights the prism in
the field of view.
5. The SRX/NET tracks a sighted prism as it is
moved to the next measurement point when
Auto Tracking is set.
4.1
Turning Operation Flow