2
Uninterruptible Power Supplies
Series
Designation
Frame Configuration Type
System kVA / kW
Number of Charger
Modules
System Type
Battery Type and Number
Strings
Output Voltage/
Frequency/Wiring
Distribution Slot 1
Distribution Slot 2
Product Type
A = 10 Bay, Xfmr Free,
1PH, cULus Listed, GS/
CE/C-tick Marked
05A = 5 kVA / 4.5 kW
N = No charger module
N = Non-redundant
NN = None (allows
for empty replacement
frames to be shipped)
A = 200V, 60Hz, L-L-G
N = None
N = None
C = Standard product
B = 16 Bay, Xfmr Free,
1PH, cULus Listed, GS/
CE/C-tick Marked
10A = 10 kVA / 9 kW
A = 1 charger module
R = Redundant Power
and Controls
C1 = 1 String, CSB
UPS 12460 F2 FR
B = 220V, 60Hz, L-L-G
1 = (2) L6-30R, (8)
5-15/20R [PD2-101]
1 = (2) L6-30R, (8)
5-15/20R [PD2-101]
C = 12 Bay Xfmr
Based, 1PH, cULus
Listed, GS/CE/C-tick
Marked
15A = 15 kVA / 13.5
kW
F = Redundant Power,
Controls, and Battery
C2 = 2 Strings, CSB
UPS 12460 F2 FR
C = 208V, 60Hz, L-L-G
2 = (4) L6-20R, (4)
5-15/20R [PD2-102]
2 = (4) L6-20R, (4)
5-15/20R [PD2-102]
D = 16 Bay Xfmr
Based, 1PH, cULus
Listed, GS/CE/C-tick
Marked
20A = 20 kVA / 18 kW
C3 = 3 Strings, CSB
UPS 12460 F2 FR
D = 240V, 60Hz, L-L-G
3 = (4) L6-30R, (4)
5-15/20R [PD2-103]
3 = (4) L6-30R, (4)
5-15/20R [PD2-103]
E = 10 Bay, Xfmr Free,
2PH, cULus Listed
C4 = 4 Strings, CSB
UPS 12460 F2 FR
E = 200/100V, 60Hz,
L-L-N-G
4 = (2) L6-30R, (2)
L6-20R, (4) 5-15/20R
[PD2-104]
4 = (2) L6-30R, (2)
L6-20R, (4) 5-15/20R
[PD2-104]
F = 16 Bay Xfmr Free,
2PH, cULus Listed
C5 = 5 Strings, CSB
UPS 12460 F2 FR
F = 220/110V, 60Hz,
L-L-N-G
5 = (2) L5-30R, (2)
L5-20R, (4) 5-15/20R
[PD2-105]
5 = (2) L5-30R, (2)
L5-20R, (4) 5-15/20R
[PD2-105]
C6 = 6 Strings, CSB
UPS 12460 F2 FR
G = 208/120V, 60Hz,
L-L-N-G
6 = (4) L6-20R, (4) L5-
20R [PD2-106]
6 = (4) L6-20R, (4) L5-
20R [PD2-106]
C7 = 7 Strings, CSB
UPS 12460 F2 FR
H = 240/120V, 60Hz,
L-L-N-G
7 = (4) L5-20R, (4)
5-15/20R [PD2-107]
7 = (4) L5-20R, (4)
5-15/20R [PD2-107]
J = 220/127V, 60Hz,
L-L-N-G
8 = (2) L6-30R, (2) L6-
20R [PD2-108]
8 = (2) L6-30R, (2) L6-
20R [PD2-108]
9 = (2) L14-30R [PD2-
109]
9 = (2) L14-30R [PD2-
109]
A = (4) IEC320-C19, (4)
IEC320-C13 [PD2-200]
A = (4) IEC320-C19, (4)
IEC320-C13 [PD2-200]
B = (2) IEC320-C19,
(8) IEC320-C13 [PD2-
201]
B = (2) IEC320-C19,
(8) IEC320-C13 [PD2-
201]
C = (12) IEC320-C13
[PD2-202]
C = (12) IEC320-C13
[PD2-202]
D = (2) IEC309-32A, (4)
IEC320-C13 [PD2-204]
D = (2) IEC309-32A, (4)
IEC320-C13 [PD2-204]
Example:
10 Bay, 1PH, 10 kVA/9 kW, No Charger Module, Non-Redundant, 2 strings, 208V, 60 Hz, L-L-G, No Distribution Slots, Standard Product
S5K
A
10A
A
N
C2
C
N
N
C
Configuration Notes:
1. Every pre-configured S5KC UPS arrives standard with one IS-UNITY-DP communications card installed. This allows you to take advantage of the
monitoring included with your system during your initial standard warranty period. Start-up services available, contact your local SolaHD sales representative
for details.
2. “Maximum Upgrade” capacity considerations. The Maximum Upgrade is the highest kVA expansion each configuration will provide without removing any
of the battery modules from the original configuration. Please consider your future expansion and redundancy needs.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com