- 39 -
3-
Remove the ring pins and change the sprockets as required by
the dose it is wished to distribute. Once modified, reassemble
the ring pins (Fig. 6.47).
VERY IMPORTANT:
TO MODIFY THE TRANS-
MISSION, SEE THE DOSAGE TABLES IN SEC-
TION 9.3.3 EXTERNAL KIT HOPPER WITH ME-
CHANICAL TRANSMISSION.
Fig. 6.47
Fig. 6.47
4-
Reassemble the chain and tension it with the take-up sprocket,
tighten the handle securely (Fig. 6.48).
5-
Use the two fasteners to assemble the chain cover (Fig.
6.49)
6-
Repeat the above steps to modify the transmission on the op-
posite side
Fig. 6.48
Fig. 6.48
BEHIND
BEHIND
TRANSMISSION BOX
TRANSMISSION BOX
Fig. 6.49
Fig. 6.49
IF THE DOSE TO BE DISTRIBUTED CANNOT BE
ADJUSTED WITH THE TRANSMISSION, THERE
IS THE POSSIBILITY OF CHANGING THE DIS-
PENSERS' STANDARD ROLLER TO A HALF-
DOSE ROLLER. IN THAT CASE, THE VALUES GIV-
EN IN THE DOSAGE TABLES FOR THIS KIT MUST
BE HALVED (FIG. 6.50).
IMPORTANT:
IF THE COULTER UNIT HAS TWO
DISTRIBUTION HEADS, ONLY ONE PRODUCT
CAN BE DISPENSED. IN THIS CASE, THE SAME
TYPE OF ROLLER MUST BE INSTALLED IN BOTH
DISPENSERS.
Fig. 6.50
Fig. 6.50
STANDARD ROLLER
STANDARD ROLLER
HALF-DOSE ROLLER
HALF-DOSE ROLLER