INSTALLATION – WATER HEATER
20
DIMENSIONS AND TECHNICAL DATA
Australian models
natural 10143200 10143240 10143260
New Zealand models
natural 10143265
propane 10143201 10143241 10143261
LPG 10143266
Rated delivery @ 40°C rise
natural
gas
propane
L/min
L/min
12.5
12.5
15
15
16
16
Rated delivery @ 40°C rise
natural
gas
universal
LPG
L/min
L/min
16
16
Recovery @ 25°C rise
natural
gas
propane
L/min
L/min
20
20
24
24
26
26
Recovery @ 25°C rise
natural
gas
universal
LPG
L/min
L/min
26
26
Mass empty
kg 20 21 21
Mass empty
kg 21
Note: Models 10143265 (natural) and 10143266 (universal LPG) are suitable for New Zealand only
Gas Details
Test Point Gas Pressure (kPa)
Hourly Gas
Consumption
(MJ)
Min Gas
Pressure
(kPa)
minimum maximum
Max Gas
Pressure
(kPa)
20 24 26 20
to
26 20 24 26 20 24 26 20
to
26
Natural
157 188 199 1.13 0.182
0.17 0.17 0.903 0.912 0.965 3.50
Propane
157 188 199 2.75 0.32 0.22 0.22 1.50 1.078 1.20
3.50
Universal LPG
- -
199 2.75 - -
0.22
- -
1.10 3.50
Model numbers: 0 = Natural, 1 = Propane. Digit 0, 1 is included in the part number as the eighth (last) digit, eg
10143240, to denote gas type.
Specifications are subject to change with ongoing product improvements.