CONNECTIONS – ELECTRICAL
All electrical work and permanent wiring must be carried out by a qualified person and in accordance
with the Wiring Rules AS/NZS 3000 and local authority requirements.
Warning:
Temperature controllers
must not
be fitted to this water heater as part of a solar water
heater system because water at a temperature much higher than the controller setting can be delivered.
The water heater is supplied with a 1.8 metre lead and plug and requires a weatherproof 240 V 50 Hz
general purpose outlet (GPO) to be located within 1.2 metres of the installation. The GPO must be clear
of the flue exhaust, draining water, gas supply pipe and water connections.
The power consumption of the water heater is:
Component
Power
consumption
Comments
Gas booster
64 Watts
66 Watts
24L, 26L Anti frost device inactive
20L Anti frost device inactive
150 Watts
Anti frost device active
The water heater will only operate on a sine wave at 50 Hz. Devices generating a square wave cannot
be used to supply power to the water heater.