CONNECTIONS – PLUMBING
All plumbing work must be carried out by a qualified person and in compliance with the Standard
AS/NZS 3500.4 and all local codes and regulatory authority requirements.
All gas work must be carried out by a qualified person and in compliance with the Standard AS 5601 or
AS/NZS 5601.1, as applicable under local regulations, and all local codes and regulatory authority
requirements.
CONNECTION SIZES
Model
10143204
10143205
10143274
10143275
Hot water connection
R 3/4
R 3/4
Cold water connection
R 3/4
R 3/4
Gas inlet connection
R 3/4
R 3/4
WATER INLET AND OUTLET
All pipe work must be cleared of foreign matter before
connection and purged before attempting to operate the
water heater. All olive compression fittings must use
brass or copper olives. Use thread sealing tape or
approved thread sealant on all fittings.
A full flow gate valve or ball valve must be installed on
the cold water line or solar preheat water line to the
water heater.
A non return valve or stop tap must not
be installed.
An acceptable arrangement is shown in
the diagram. Refer also to
page 17 and to
on page 16.
A disconnection union must always be provided at the
cold water (solar preheat) inlet and hot water outlet on
the water heater to allow for disconnection of the water
heater.
Insulation used on the cold and hot water lines must
extend up to the cold water (solar preheat) inlet and hot
water outlet of the water heater.
Notes:
It is essential all pipe connections be correctly aligned, otherwise component connections within the
water heater may be strained and / or components themselves misaligned. It is recommended also,
wherever possible, pipe connections be made at the water heater first and final pipe runs be made in
soft copper pipe to allow some adjustment for misalignment.
Use the spanner flats on the water heater fittings and take care to avoid twisting the water inlet and
outlet pipes inside the jacket.
This model in-series gas booster
does not
need to be installed with a solar transfer valve if the solar
water heater has an over temperature protection system.
It is recommended to install a solar transfer valve if the solar water heater does not have an over
temperature protection system.
SOLAR PREHEAT WATER & GAS CONNECTION DETAIL
HOT
WATER
POWER
CORD
GATE VALVE
OR
BALL VALVE
GAS
COCK
SOLAR
PREHEAT
WATER
GAS
In-series Gas Booster
Solar Preheat and Hot Water
and Gas Connection Details