WATTrouter ECO - user manual
www.solarcontrols.cz
How to fit and setup the device
Page 10 from 66
R2_2 – relay output 2 – terminal 2
FB – input for connection of impulse output of external energy meter (0V or +5V)
S4- – external output for SSR 4 – negative electrode (open collector)
GND – common wire coming from the current sensing module (must always be connected)
I_L1 – electric current measuring input L1 from the current sensing module (must always be
connected)
I_L2 – electric current measuring input L2 from the current sensing module
I_L3 – electric current measuring input L3 from the current sensing module
LT – low tariff signal detection (0V or +5V)
S+ – external output for SSR – common positive electrode (+5V)
S1- – external output for SSR 1 – negative electrode (open collector)
S2- – external output for SSR 2 – negative electrode (open collector)
S3- – external output for SSR 3 – negative electrode (open collector)
USB – USB interface connector (USB B)
LED description:
PWR – regulator power on light (green)
COM – communication light - USB interface (yellow)
ERR – error status light (red)
S1 – external output for SSR 1 - activity indication light
S2 – external output for SSR 2 - activity indication light
S3 – external output for SSR 3 - activity indication light
S4 – external output for SSR 4 - activity indication light
R1 – relay output No. 1 - activity indication light
R2 – relay output No. 2 - activity indication light
Wireless PWR – LED indicator of SC-Gateway (optional accessories)
Wireless LINK – LED indicator of SC-Gateway (optional accessories)
Figure 2: Terminals description of sensing module (top view).
Current sensing module terminal description:
I_L1 – current measuring output L1 (must be always connected)
I_L2 – current measuring output L2
I_L3 – current measuring output L3
GND – common wire (must always be connected)
Connect the controller according to sample connection diagrams shown lower on figures. If you observe basic
principles, connections may be combined in various ways. You may connect any number of loads to any
outputs. In certain cases you may remove certain phase cable from the measuring, etc.