Time schedule for boiler is set the same as in example No. 1.
Two time schedules are assigned for pool filtering pump. The first of them describes restriction of the output
during "daytime" between 8:00 and 23:00. This restriction ensures the motor runs approximately 6 hours and
therefore, it applies only if the daily energy counter exceeds 1.8 kWh. The second time schedule restricts
operation of the motor between 23:00 and 5:00 without any special requirements or conditions. The necessary
prerequisite for correct application of these two time schedules is correct configuration of daily energy counter
reset. As reset mode there must be selected "at sunrise" or "at fixed time". The fixed time for second case
should be selected in the morning before 8:00.