WATTrouter ECO - user manual
www.solarcontrols.cz
How to fit and setup the device
Page 65 from 66
Relay output off-delay time
Programmable (minimum of 2s)
Other parameters
Maximum diameter of wires connected to terminals
2.5 mm
Maximum diameter of wires passing through
measuring transformers
9 mm (including insulation)
Distance of the current sensing module and the
regulator
<2 m (longer wires are acceptable, but they reduce
the accuracy approx. by 0.2% per 2m).
Distance of the regulator and solid state relay
<10 m
Working position
any
Mounting
Regulator: DIN 35mm or wall mounted using 2
screws with round or sink head and with diameter of
up to 6mm.
Current sensing module: DIN 35mm or wall mounted
using 1 screw with round or sink head and with
diameter of up to 6mm.
Overvoltage category
III
Electric strength
4 kV / 1 min (power supply (L, N)-output, output -
output, power supply-current input, external output,
etc.(GND,I_L…,LT,FB…,S+,S1- ,S2- ,S3- , S4-))
Pollution degree
2
Operational temperature range
-20°C to +40°C
Storage temperature range
-40 °C to +80 °C
Protection (power supply)
B6A
IP code
Regulator and current sensing module: IP 20
Dimensions (WxHxD)
Regulator: 70x110x64mm (4 modules)
Current sensing module: 70x110x64mm (4 modules)
Weight
Regulator: 350g
current sensing module: 100g
Noise level (including SSR)
Only passive cooling, for power SSR is necessary to
ensure sufficient heat dissipation.
Battery for real-time backup
CR2032 lithium, usual lifetime> 6 years
Warranty period
24 months
RECYCLING
After the product life is over the product may be disassembled, recycled or disposed of at a save dumpsite.
Legal regulations regarding electronic waste treatment have to be observed in respective country.
Do not dispose in regular household waste!