background image

Professional, Vision

13

1408TU0710

 

J

Maintenance and cleaning 

Usually, the modules are automatically cleaned 
by rain. With an inclination of more than 15° the 
modules generally need no additional cleaning. In 
the case of severe contamination, we recommend 
that the modules are cleaned with ample water 
and without cleaning agents. 

In the case of severe contamination, we 
recommend cleaning with plenty of water with 
a low lime content. Please do not use a nozzle 
attachment, and ensure that only moderate 
water pressure is used. Using cleaning products 
and scratching cleaning devices will damage the 
special anti-reflective coating and render the 
product and performance guarantees void. Under 
no circumstances may contaminants be scratched 
or rubbed off without moisture. Damage to the 
highly efficient anti-reflective surface may change 
the visual appearance of the module surface and 
result in decreased performance.

Use of automatic cleaning machines for solar 
energy systems is at your own risk, and is not 
authorised by Solar-Fabrik AG in any way.  

Inspect the installation on a regular basis and 
check it for
 

 

X

secure fixing and corrosion-free condition of all 
mountings 

 

X

secure connection, cleanliness, integrity and 
corrosion-free condition of all wire connections 

 

X

transition impedances of the potential 
equalization

 

J

Information about liability and 
revision level of the instructions

If any of the instructions given in the user 
information are not adhered to, Solar-Fabrik 
AG will not guarantee the availability and 
functionality of the modules. Since the compliance 
with the said safety instructions as well as 
the conditions and methods for installation, 
operation, usage and maintenance of the modules 
cannot be checked or monitored by Solar-Fabrik 
AG, Solar-Fabrik AG does not accept any liability 
for damage due to improper use, incorrect 
installation, operation, usage or maintenance. 
The text and the figures of this installation guide 
comply with the state of technology at the time of 
printing.

Subject to alterations.

Summary of Contents for Professional 54

Page 1: ...Play it safe Installation guide solar modules Professional Vision...

Page 2: ...d The technical information at the time of production of the product are valid Solar Fabrik AG Freiburg 2014 DIN EN ISO 9001 Quality management system DIN EN ISO 14001 Environmental management system...

Page 3: ...Professional Vision 3 Vision 54 frameless Professional 60 Vision 60 Professional 54 1408TU0710 Installation guide...

Page 4: ...reme Danger due to electrical shock Solar modules generate electricity When exposed to light a voltage occurs which can be dangerous and life threatening Even though the individual modules generate a...

Page 5: ...ss are approved for operation in installations with unrestricted access Professional and Vision modules from Solar Fabrik AG which are qualified under EN 61730 and have been properly installed meet th...

Page 6: ...carry out a proper grounding If an external lightning protection system has been already installed the PV system has to be integrated in the existing lightning protection concept by a specialist Count...

Page 7: ...hen turn the screw another quarter or half turn The thread cutting screw should be torqued by 20 4 lb in and 24 8 lb in 2 3 and 2 8 Nm J J Wire placement Insert the cable into the wire slot Then push...

Page 8: ...taken that the module is not exposed to any negative mechanical or electrical influence from other system components Only connect modules with the same rated current in series and modules with the sa...

Page 9: ...n of heat with adverse effects on the performance can be avoided J J Secure attachment To ensure that modules are installed correctly make sure to securely attach the modules at least four points Fram...

Page 10: ...Vision 60 L C 3 990 340 400 340 400 1677 240 240 500 240 240 500 240 240 1000 Vision 60 Professional 54 L C 3 990 1503 210 210 460 210 210 460 240 240 1000 Professional 54 1408TU0710 Installing the m...

Page 11: ...modules from the back example B using the provided attachment holes Use a torque wrench for installation The required tightening torque for the above samples is 14 8 lb ft 20 Nm Use M6 bolts made of V...

Page 12: ...der to minimize the voltage drop For further connections of the modules only appropriate cables with a minimum conductor cross section of 4 mm must be used J J Protect the wires from adverse environme...

Page 13: ...of automatic cleaning machines for solar energy systems is at your own risk and is not authorised by Solar Fabrik AG in any way Inspect the installation on a regular basis and check it for X X secure...

Page 14: ...Professional Vision 14 1408TU0710 Notes...

Page 15: ...Professional Vision 15 1408TU0710...

Page 16: ...Play it safe Solar Fabrik AG Munzinger Str 10 79111 Freiburg Deutschland Telefon 49 0 761 4000 0 Telefax 49 0 761 4000 199 www solarfabrik de Status 07 08 2014 Document number 1408TU0710...

Reviews: