Safety information

 

J

General safety information

The operation and maintenance of a PV system 
require a substantial level of technical knowledge. 
Therefore, any work on the system may only be 
carried out by qualified and authorized personnel. 
Make sure to read these mounting instructions 
carefully before installing, commissioning 
or servicing the PV system and keep these 
instructions in a well accessible location. Failure to 
comply with these safety instructions may result in 
personal injury and product damage. Please keep 
children away!

We strive to be the leader in innovation and 
research, while continuing to improve our 
products. 

For this reason we reserve the right to make 
changes to this installation guide without prior 
notice.

 

J

Important safety instructions

The use of these modules must comply with 
original design purposes. The modules should not 
be altered technically. When mounting, make sure 
that the valid local building regulations, standards 
and accident prevention regulations are adhered 
to. Make sure that all required safety instructions 
for the mounting and operation of any further 
system components are also adhered to.

 

J

Warning: Extreme Danger 
due to electrical shock!

Solar modules generate electricity. When exposed 
to light, a voltage occurs, which can be dangerous 
and life-threatening. Even though the individual 
modules generate a relatively low voltage of 
50 V DC, the voltage will accumulate as soon as 
several modules are connected in series. Modules 
connected in parallel result in accumlation 
of the currents. Although the fully insulated 
plug contacts are designed to protect against 
accidental contact, the following instructions must 
be followed when handling the solar modules in 
order to avoid combustion, spark formation and, 
above all, fatal electrical shocks: 

 

X

Never insert electrically conducting pieces into 
the plugs and sockets!

 

X

Do not wear metallic jewelry during 
mechanical and electrical installation!

 

X

Keep the tools and work area dry! Only install 
solar modules and wires with dry plugs and 
sockets! 

 

X

Maintain utmost caution and care! When 
working on the wires, always use both tools 
and gloves which are insulated! 

 

X

Do not disassemble the modules! Never 
remove parts or name plates fitted by the 
manufacturer! Only use flawless modules! Do 
not treat the back side of the modules with 
sharp objects, paints or adhesives! 

 

X

Do not expose modules to artificially 
concentrated sunlight

It is absolutely necessary that the wiring of the 
modules is only carried out by qualified and 
authorized personnel! 

Summary of Contents for Professional 54

Page 1: ...Play it safe Installation guide solar modules Professional Vision...

Page 2: ...d The technical information at the time of production of the product are valid Solar Fabrik AG Freiburg 2014 DIN EN ISO 9001 Quality management system DIN EN ISO 14001 Environmental management system...

Page 3: ...Professional Vision 3 Vision 54 frameless Professional 60 Vision 60 Professional 54 1408TU0710 Installation guide...

Page 4: ...reme Danger due to electrical shock Solar modules generate electricity When exposed to light a voltage occurs which can be dangerous and life threatening Even though the individual modules generate a...

Page 5: ...ss are approved for operation in installations with unrestricted access Professional and Vision modules from Solar Fabrik AG which are qualified under EN 61730 and have been properly installed meet th...

Page 6: ...carry out a proper grounding If an external lightning protection system has been already installed the PV system has to be integrated in the existing lightning protection concept by a specialist Count...

Page 7: ...hen turn the screw another quarter or half turn The thread cutting screw should be torqued by 20 4 lb in and 24 8 lb in 2 3 and 2 8 Nm J J Wire placement Insert the cable into the wire slot Then push...

Page 8: ...taken that the module is not exposed to any negative mechanical or electrical influence from other system components Only connect modules with the same rated current in series and modules with the sa...

Page 9: ...n of heat with adverse effects on the performance can be avoided J J Secure attachment To ensure that modules are installed correctly make sure to securely attach the modules at least four points Fram...

Page 10: ...Vision 60 L C 3 990 340 400 340 400 1677 240 240 500 240 240 500 240 240 1000 Vision 60 Professional 54 L C 3 990 1503 210 210 460 210 210 460 240 240 1000 Professional 54 1408TU0710 Installing the m...

Page 11: ...modules from the back example B using the provided attachment holes Use a torque wrench for installation The required tightening torque for the above samples is 14 8 lb ft 20 Nm Use M6 bolts made of V...

Page 12: ...der to minimize the voltage drop For further connections of the modules only appropriate cables with a minimum conductor cross section of 4 mm must be used J J Protect the wires from adverse environme...

Page 13: ...of automatic cleaning machines for solar energy systems is at your own risk and is not authorised by Solar Fabrik AG in any way Inspect the installation on a regular basis and check it for X X secure...

Page 14: ...Professional Vision 14 1408TU0710 Notes...

Page 15: ...Professional Vision 15 1408TU0710...

Page 16: ...Play it safe Solar Fabrik AG Munzinger Str 10 79111 Freiburg Deutschland Telefon 49 0 761 4000 0 Telefax 49 0 761 4000 199 www solarfabrik de Status 07 08 2014 Document number 1408TU0710...