17
April 2021
|
Solar Stik
®
, Inc.
PRELIMINARY DRAFT
24VDC HyPR 3000 Operator and Maintenance Manual
The Charger
• The HyPR charger provides full power (3000 W) up to ~158 ºF (30 ºC). At 158 ºF (70 ºC) it will
reduce power ~30% of full-rated power until it cools and resumes normal, full-rated output.
• Below 80 ºF (27 ºC), the HyPR can process around 2000 W continuous for battery charging (with
no loads connected).
How to Minimize Derating
• Do not overload the HyPR. Manage power processing demand by paying close attention to what
is “plugged in. Prioritize critical loads.
• Shade the HyPR 3000 to reduce solar loading. Solar Stik data indicate that solar loading of a
Pelican case can increase internal heat by ~40 ºF (~ 22 ºC) above ambient.
• Do not block airflow into or out of the HyPR; give is space to breathe.
• Clean or replace the air intake filters regularly.