April 2021
|
Solar Stik
®
, Inc.
26
|
24VDC HyPR 3000 Operator and Maintenance Manual
PRELIMINARY DRAFT
V
oc
: 30-57 VDC
15 A max
400 W max
120-230 VAC
30 A Max
AC Power Input Port
Figure 10. HyPR 3000 AC power input port
Figure 11. HyPR 3000 solar input port
Solar Input Port
The HyPR accepts power from PV arrays to charge connected ESMs. Specifications for the solar
charge controller and compatible PV arrays are on the HyPR 3000 Faceplate.
Functioning PV
arrays must be connected for the DC INTERFACE to calculate and report ESM state of charge
(SOC)
Pins A and C are the current conductors, pin B is unused.
Connect AC power sources to the 120-230VAC INPUT port. The HyPR 3000 accepts “universal” (85
- 264 V) power. Power via this connection charges batteries and supports DC loads connected the
24VDC IN/OUT and NATO ports.
OR
Generator
Grid
(A)
Neg-
(C)
Pos+
(B)
N/A