24VDC HyPR 3000 Operator and Maintenance Manual
PRELIMINARY DRAFT
Expander Pak Only Port
Connect Expander Paks (ESMs) to this metered Inter-Connect port.
Figure 13. HyPR Expander Expander Pak / ESM connection port
Use Inter-Connect cables to connect multiple ESMs to an Inter-Connect Strip 7 and to the HyPR
3000 EXPANDER PAK ONLY port.
A single battery is enough to power up the HyPR 3000 internal circuits and user interface as well as
to support small loads. However, additional batteries must be connected for the HyPR to operate at
its full rated capacity (see
Battery Requirements for Operation
).
Note:
The total Ah capacity of all connected ESMs must be programmed into the HyPR, using the
DC interface, for the HyPR DC interface to report battery SOC accurately.
Inter-Connect Strip 7
> 96 ADC = full capacity operation