39
April 2021
|
Solar Stik
®
, Inc.
PRELIMINARY DRAFT
24VDC HyPR 3000 Operator and Maintenance Manual
MPG Parallel Connections
The HyPR has the ability to receive power from two (2) MPGs simultaneously. The power output from
each of two generators is merged into a single “Y” cable connected to a single power input port on
the left side of the HyPR (Figure 12). The mode of each generator is controlled independently and
each has its own communication cable to the HyPR. The LED over each Generator Control Switch
(HyPR Faceplate) blinks slowly when functioning in Auto mode, more rapidly when manual On mode,
and very rapidly when there is a generator fault. The LED does not blink when the switch is in the Off
position.
To HyPR AC
input port
Figure 29. Connecting two 1 kW generators in parallel
with the “Y” AC power cable.
Novatio AC
Power “Y”
Cable