43
April 2021
|
Solar Stik
®
, Inc.
PRELIMINARY DRAFT
24VDC HyPR 3000 Operator and Maintenance Manual
Item #
Item to be
Inspected
Interval
Procedures
Non-mission Capable
1
Visual
inspection of
24VDC HyPR
3000
M
1. Inspect case for visible damage
and missing items.
2. Clean excessive dust or dirt
accumulation from the exterior,
interior and all connectors.
3. Close all unused connector
covers.
~If the case is broken or split or
if connectors are damaged, do
not place into service.
2
Air Intake
Filters
M
1
1. Remove the two (2) air intake
filters.
2. Wash with water and dry the filter.
Reinstall.
3. If the filter is damaged or cannot
be cleaned --replace it.
~If the filter cannot be cleaned,
is too damaged to function
properly and a replacement is
not immediately available, the
unit is partially mission capable.
Replace the filter as soon as
possible to restore the unit to
fully mission capable.
Preventive Maintenance Checks and Services (PMCS)
HyPR 3000 Air Intake Filter Cleaning
There are two (2) air intake filters on the HyPR, one (1) on the front and one (1) on the back.
Note:
See also Figure 16 on page 30.
1
Use a #2 cross-tip screwdriver to remove the four (4) fasteners from the vent shroud and remove
the louvered vent cover to access the filter. The four (4) fasteners hold both parts onto the case.
Figure 32. Fastener locations on vent shroud
Back
Front
Maintenance