AC IN and AC OUT Breakers
– Circuit breakers protect against overcurrent conditions in dedicated
circuits. If too much amperage flows due to short-circuit, inadequate or improper loading, or
component failure, these will protect the system and operator. The LED associated with the breaker
is green when there is power to the breaker from an AC power source. The LED will be illuminated
even when the breaker is in the OFF position.
24 VDC 5 A Output and Breaker
– These terminal posts supply power to the RMK if present. The
LED associated with the breaker is green when the circuit is operating normally.
Remote Monitoring Kit (RMK)
– This optional (sold separately) device reports, records, and stores
28 PRO-Verter and System metrics. See
section.
RMK Connections Ports and Cables
– These provide communication connections between the
RMK, the PRO-Verter and remote access monitoring equipment (via the Tech Port). See
System Recovery Switch
– This switch provides a way to restart a System using 120 VAC power, if
the System batteries are overdischarged/there is no 24 VDC power source available. See
System with Overdischarged Batteries
section.
AC Input Reverse Polarity Indicator LED –
LED will light red when reverse polarity is sensed on
the AC input.
USB Charging Ports (x2) –
Provides 5 VDC / 2.1 A. Charging only. No data.