PRO-Verter BMK Circuit Operational Statuses
A Battery Monitor status message may be an operational or fault message. Access the METER: 05A
BMK Status menu to view its current operating status. The status is important when determining if
the circuit is working correctly or for troubleshooting a Battery Monitor installation.
BMK Ready
The Battery Monitor is communicating correctly with the inverter/charger.
The following “SOC” statuses indicate the battery’s current state of charge (SOC) Access the
METER: 05B Battery SOC menu to view the Battery Monitor’s current SOC status
Think’n
When the BMK sense module is first connected, the batteries need to be fully charged (i.e., SOC =
100%) to establish a SOC reference point.
###%
The batteries are fully charged; the display has changed from “Think’n” to “100%” and is ready to
provide accurate SOC percentage values.
Resolving BMK Faults Using the LCD User Interface
For the three Battery Monitor faults that follow, refer to their respective solutions.
Factory Fault
The Battery Monitor has lost its factory-set internal calibration reference.
Solution:
Reset the Battery Monitor by removing all power from the PRO-Verter. If the fault remains
or returns after resetting, the unit may require repair. Contact your Field Service Representative.
Unknown Fault ##
This fault message displays when the Battery Monitor has sent a fault code that is not recognized by
the user interface.
Solution:
Contact your Field Service Representative
Power-up Fault
The Battery Monitor power-up sequence failed.
Solution:
Restart the PRO-Verter.
PRO-Verter Battery Monitoring Kit (BMK) Troubleshooting