41
December 2020
|
Solar Stik
®
, Inc.
SYSTEM SETUP AND OPERATION GUIDE FOR THE SOLAR STIK USAF G-BOSS MEDIUM AND HEAVY HYBRID POWER SYSTEM
PRELIMINARY DRAFT
CTRL
01 AC In Control
Auto Connect
02 CHG Control
Multi-Stage
03 Gen Control
AUTO
Set AC In Control
Auto Connect
Set CHG Control
Multi-Stage
Set Gen Control
AUTO
Set AC In Control
VDC Connect
Set CHG Control
Start Float
Set Gen Control
ON
Set AC In Control
Time Connect
Set CHG Control
Start Bulk
Set Gen Control
OFF
Set AC In Control
SOC Connect
Set AC In Control
AC In - Disabled
04 PT Control
Press Select
See
Setup Button 04 Menu Options
Feature not utilized by
PRO-Verter 5000
METER
Status
01 DC Meters
Status
02 AC Meters
Status
04 AGS Meters
01A DC Volts
26.2 VDC
02A Output Volts
120 VAC/ 60.0 Hz
01B DC Amps
0 Amps
02E Input AC1
120 Volts AC
02B Load Amps
0 Amps AC
02C Input Amps
0 Amps AC
02D Inv/Chg Amps
0 Amps AC
02F Input AC2
0 Volts AC
Status
03 Timers
03A Charge Time
Status
03B Since Absorb
27.8 VDC
03C Since EQ
0.0 Hours
CTRL Button Menus
METER Button Menus: Read-only Displays
Continued on next page
Programming Menu Map
R
R
R
R
R
R
R
R
P
P
P
R
R
R
R
FAVS Button Menus
FAVS
F1 Battery Type
CC/CV
F4 LBCO
24.0 Volts
F2 AmpHour Size
420 AH
F3 AC Input
Amps = 25A
F5 Gen Run VDC
Set Stop Gen
Volts = 28.8
Set Stop Volts
Delay = 1 Min
Set Start Gen
Volts = 25.6
Set Start Volts
Delay = 15 sec
Set CV Chg Done
HOLD CV/CHG VDC
Set CV Charge
Volts =
29.0
Set Max Charge
AMPS =
100