120
Enfinity
29
Enfinity
29.1
Enfinity
Termination
Addressing
Interface
-
Yes
RS422
Overview
•
Integrated interface.
•
2 RJ11 sockets inside the inverter.
•
4-pin wiring - only on RS485/422 B or C connection of the Solar-Log™.
•
Communication address does not have to be assigned.
•
Installation steps:
•
Switch off the inverters and Solar-Log™.
•
Connect inverters to the Solar-Log™.
•
Connect the inverters to each other.
Note
Only connect inverter using the RS485/422 B or C interface.
Connect inverters to the Solar-Log™.
The wiring is done using a
•
self-made, shielded 4 wire data cable and terminal block connector.
•
Where to connect: RJ11 socket on the inverter.
Procedure
Open the inverter as shown in the inverter‘s instructions.
1. If you are making the cable yourself, connect the wires as shown in the following diagram:
Solar-Log™ terminal strip connector
Inverter terminal strip
Terminal
Terminal
►
1
►
Pin 3 - RX+
►
4
►
Pin 4- RX-
►
5
►
Pin 1 - TX+
►
6
►
Pin 2 TX-
2. Insert the RJ1plug into any RJ11 socket on inverter 1.
3. Close the inverter if no other inverters are to be connected.
4. Insert the terminal block connector into the Solar-Log™ RS485/422 B or C socket.
Summary of Contents for Solar-Log
Page 1: ...1 Components Connection Manual V 4 2 3 Solar Log EN ...
Page 20: ...20 01 Inverter ...
Page 398: ...398 Appendix 113Appendix 113 1 SMA mixed wiring Fig SMA mixed wiring ...
Page 402: ...402 02 Meter ...
Page 444: ...444 03 Battery Systems ...
Page 456: ...456 sonnen Note Only one battery system can be connected to a Solar Log device ...
Page 463: ...463 04 Heating rods ...
Page 470: ...470 05 Heating pumps ...
Page 478: ...478 06 Sensors ...
Page 488: ...488 07 Pyranometer ...
Page 495: ...495 08 Smart Plug components ...
Page 502: ...502 09 Power Charging Stations ...