226
Powercom
Solar-Log™ terminal strip connector
Inverter terminal strip
Terminal
PIN
►
1
►
R+
►
1
►
T+
►
4
►
R-
►
4
►
T-
4. Close the inverter if no other inverters are to be connected.
5. Insert the terminal block connector into the Solar-Log™ RS485 socket.
Connect the inverters to each other
•
Connect using a 4 wire, shielded data cable
•
Where to connect: Terminal strip inside the inverter on the retrofitted RS485 interface card
Procedure
1. Open the inverter as shown in the inverter's instructions
2. Connect terminals R+, T+, R- and R+ of inverter 1 to the corresponding terminals on inverter 2
3. Connect the other inverters to each other in the same way
4. Close inverters