235
Q3
Procedure
1. Connect wires as shown in the diagram below.
Solar-Log™ terminal strip connector
Inverter terminal strip
Terminal
Terminal
►
1
►
1 (RS485-A)
►
3
►
3 (GND)
►
4
►
2 (RS485-B)
2. If no further inverter is connected, terminate the inverter according to the instructions for the inverter.
3. Insert the terminal block connector into the Solar-Log™ RS485 socket.
Connect the inverters to each other
•
Connect using a self-made daisy chain cable.
•
Where to connect: X2 connection socket on outside of the inverter.
Procedure
1. Insert the plug into socket X2 on inverter 1.
2. Insert the other end of the wire into the X2 socket on inverter 2.
3. Connect the other inverters to each other in the same way.
4. Terminate the last inverter in accordance with the inverter instructions.
Allocate communication address
•
Recommendation: Continuous numbering starting with 1.
•
Default settings on the inverter: Communication address 1
•
Setting: Using the inverter operating display Notes
-
Select Address for ProLog in the Communication / RS485 menu
-
Set Protocol type COM 1 to 9 in the Communication menu
•
Procedure: Start according to the inverter's instructions
Summary of Contents for Solar-Log
Page 1: ...1 Components Connection Manual V 4 2 3 Solar Log EN ...
Page 20: ...20 01 Inverter ...
Page 398: ...398 Appendix 113Appendix 113 1 SMA mixed wiring Fig SMA mixed wiring ...
Page 402: ...402 02 Meter ...
Page 444: ...444 03 Battery Systems ...
Page 456: ...456 sonnen Note Only one battery system can be connected to a Solar Log device ...
Page 463: ...463 04 Heating rods ...
Page 470: ...470 05 Heating pumps ...
Page 478: ...478 06 Sensors ...
Page 488: ...488 07 Pyranometer ...
Page 495: ...495 08 Smart Plug components ...
Page 502: ...502 09 Power Charging Stations ...