The same protocol must be selected on both devices In order to ensure correct communication bet-
ween the Solar-Log™ and the inverters.
Protocol selection for device detection:
•
Q3: Protocol 1
•
Q3: Protocol 9
The following types are to be connected according to this diagram:
•
QX12000
•
QX14000
Overview
•
Integrated interface
•
Where to connect: Round pin plug on the outside of the inverter
•
3-pin wiring
•
Communication address must be allocated
•
Inverters must be grounded otherwise this could lead to problems with inverter detection
•
Installation steps
•
Switch off the inverters and Solar-Log™
•
Connect inverters to the Solar-Log™
•
Connect the inverters to each other
•
Allocate communication address
Connect inverters to the Solar-Log™
•
self-made, shielded 3 wire data cable and terminal block connector.
Procedure
1. If you are making the cable yourself, connect the wires as shown in the following diagram:
Solar-Log™ terminal strip connector
Inverter terminal strip
Terminal
Terminal
►
1
►
2 - Data +
►
3
►
3 - Ground
►
4
►
4 - Data -
2. Terminate pin 1 on the terminal block connector and pin 4 on the Solar-Log
TM
using the 120
Ω
terminal resis-
tor.
3. Terminate on the inverter in accordance with the manufacturer‘s handbook.
4. Insert the terminal block connector into the Solar-Log™ RS485 socket.
Summary of Contents for Solar-Log
Page 1: ...1 Components Connection Manual V 4 2 3 Solar Log EN ...
Page 20: ...20 01 Inverter ...
Page 398: ...398 Appendix 113Appendix 113 1 SMA mixed wiring Fig SMA mixed wiring ...
Page 402: ...402 02 Meter ...
Page 444: ...444 03 Battery Systems ...
Page 456: ...456 sonnen Note Only one battery system can be connected to a Solar Log device ...
Page 463: ...463 04 Heating rods ...
Page 470: ...470 05 Heating pumps ...
Page 478: ...478 06 Sensors ...
Page 488: ...488 07 Pyranometer ...
Page 495: ...495 08 Smart Plug components ...
Page 502: ...502 09 Power Charging Stations ...