251
Rishabh Instruments Pvt. Ltd.
72 Rishabh Instruments Pvt. Ltd.
72.1 Rishabh - Radius
Termination
Addressing
Interface
-
Yes
RS485
Selections available under Rishabh; Type: „Radius“; Interface: „RS485“
Supported models (as of firmware 4.2.0):
•
10KwAE 1mppt
•
10KwAE 2mppt
•
12KwAE 1mppt
•
12KwAE 2mppt
•
15KwAE 2mppt
•
18KwAE 2mppt
•
20KwAE 2mppt
•
20KwAE 3mppt
•
10KwEE 1mppt
•
15KwEE 1mppt
•
20KwEE 1mppt
Overview
•
Integrated interface.
•
Where to connect: Terminal strip inside the inverter.
•
2-pin wiring.
•
The communication address has to be assigned.
•
Installation steps:
•
Switch off the inverters and the Solar-Log™.
•
Connect the inverters to the Solar-Log™.
•
Assign the communication address.
•
Terminate inverter.
Connect the inverters to the Solar-Log™
The wiring is done using a:
•
self-made, shielded 2-wire data cable and terminal block connector.
Note
Rishabh have two RS485 connections (A and B). Due to the required baud rate of 38400, Solar-Log™
only supports the RS485 A connection.
Summary of Contents for Solar-Log
Page 1: ...1 Components Connection Manual V 4 2 3 Solar Log EN ...
Page 20: ...20 01 Inverter ...
Page 398: ...398 Appendix 113Appendix 113 1 SMA mixed wiring Fig SMA mixed wiring ...
Page 402: ...402 02 Meter ...
Page 444: ...444 03 Battery Systems ...
Page 456: ...456 sonnen Note Only one battery system can be connected to a Solar Log device ...
Page 463: ...463 04 Heating rods ...
Page 470: ...470 05 Heating pumps ...
Page 478: ...478 06 Sensors ...
Page 488: ...488 07 Pyranometer ...
Page 495: ...495 08 Smart Plug components ...
Page 502: ...502 09 Power Charging Stations ...