292
SiNeng
Connect the inverters to each other
•
Where to connect: Terminal block inside the inverter.
•
Connect the inverters to each other according to the inverter instructions.
Assign the communication address
•
Recommendation: Continuous numbering starting with 1.
•
Setting: Via operating display (on the inverter) or via APP or via a software tool (please follow the inverter
instructions).
•
Procedure: Start according to the inverter‘s instructions.
Detection via the Solar-Log™ WEB Interface
•
For detection on the Solar-Log™, select the device class under the menu
Configuration | Device | Definition
| Interface
with the plus symbol and then select SiNeng as the manufacturer, SP as the type and the interfa-
ce. Confirm your selection with
OK.
•
Save your selections and then start the Device Detection under
Configuration | Device | Detection
and start
the device detection.
Detection from the Solar-Log 1200
•
When using the Solar-Log 1200, the detection can also be started from the display. Select the settings
►
Start
►
Initial Configuration
►
Page 2 „Devices“
►
ADD and select „Inverter,“ „SiNeng“ and the interface „RS485.“
Save and start the Device Detection.
Note
A maximum of 32 inverters can be connected per RS485 bus.
Summary of Contents for Solar-Log
Page 1: ...1 Components Connection Manual V 4 2 3 Solar Log EN ...
Page 20: ...20 01 Inverter ...
Page 398: ...398 Appendix 113Appendix 113 1 SMA mixed wiring Fig SMA mixed wiring ...
Page 402: ...402 02 Meter ...
Page 444: ...444 03 Battery Systems ...
Page 456: ...456 sonnen Note Only one battery system can be connected to a Solar Log device ...
Page 463: ...463 04 Heating rods ...
Page 470: ...470 05 Heating pumps ...
Page 478: ...478 06 Sensors ...
Page 488: ...488 07 Pyranometer ...
Page 495: ...495 08 Smart Plug components ...
Page 502: ...502 09 Power Charging Stations ...