304
SMA
84.7 SMA Speedwire
Note
The trademark "Speedwire" is registered trademark of SMA Solar Technology AG in many countries.
Termination
Addressing
Interface
No
No
Ethernet/RJ45
Select “SMA: Speedwire“ for the device detection.
Overview
•
Integrated or retrofitted Speedwire interface
•
The inverter's IP address has to be assigned.
•
Connected using network cable (patch cable) and Ethernet router or switch
•
Installation steps
•
The inverter's has to be assigned a static IP address
•
Switch off the inverters and Solar-Log™
•
Connect inverters to the Solar-Log™ (RJ45)
•
Connect the inverters to each other (RJ45)
Retrofitting the inverter with a SMA Speedwire module
Procedure
►
Install the original Speedwire module in the inverter according to the interface card installation instructions.
Connect inverters to the Solar-Log™
The wiring is done using a
•
network cable (patch cable/crossover cable) and the
•
Ethernet router or switch.
Procedure
1. Open the inverter as shown in the inverter's instructions.
2. Pull the network cable through the inverter's cable opening and connect it to the Speedwire interface.
3. Close the inverter cover if no other inverters are to be connected.
4. Plug the network cable into the RJ45 socket (Ethernet) on the Solar-Log™.
Connect the inverters to each other
The inverters are connected together using
the RJ45 interface and, if needed, a router or switch.
Connection setup according to the inverter's instructions.
Summary of Contents for Solar-Log
Page 1: ...1 Components Connection Manual V 4 2 3 Solar Log EN ...
Page 20: ...20 01 Inverter ...
Page 398: ...398 Appendix 113Appendix 113 1 SMA mixed wiring Fig SMA mixed wiring ...
Page 402: ...402 02 Meter ...
Page 444: ...444 03 Battery Systems ...
Page 456: ...456 sonnen Note Only one battery system can be connected to a Solar Log device ...
Page 463: ...463 04 Heating rods ...
Page 470: ...470 05 Heating pumps ...
Page 478: ...478 06 Sensors ...
Page 488: ...488 07 Pyranometer ...
Page 495: ...495 08 Smart Plug components ...
Page 502: ...502 09 Power Charging Stations ...