SolaX Power X1
Termination
Addressing
Interface
Yes
Automatic
RS422
The following types are to be connected according to this diagram:
•
SL-TL1500, SL-TL2200, SL-TL2500, SL-TL2800, SL-TL3000, SL-TL3300T, SL-TL3600T, SL-TL4400T, SL-TL5000T
Select SolaXPower X1 during the inverter detection.
Overview
•
Integrated interface
•
2 RJ45 sockets on the outside of the inverter
•
4-pin wiring - only on RS485/422 B or C connection of the Solar-Log™
•
Communication address does not have to be assigned
•
Installation steps
•
Switch off the inverters and Solar-Log™
•
Connect inverters to the Solar-Log™
•
Connect the inverters to each other
Note
Only connect inverter using the RS485/422 B or C interface.
Connect inverters to the Solar-Log™.
The wiring is done using a
•
self-made, shielded 8 wire data cable and terminal block connector.
•
Where to connect: RJ45 socket on the inverter
Caution
Risk of damage to the unit!
The Solar-Log™ also has an RJ45 socket, which must never be connected to the RJ45 socket on the
inverter.
►
Only connect inverters via the RS485/422 Solar-Log™ interface(s).
Summary of Contents for Solar-Log
Page 1: ...1 Components Connection Manual V 4 2 3 Solar Log EN ...
Page 20: ...20 01 Inverter ...
Page 398: ...398 Appendix 113Appendix 113 1 SMA mixed wiring Fig SMA mixed wiring ...
Page 402: ...402 02 Meter ...
Page 444: ...444 03 Battery Systems ...
Page 456: ...456 sonnen Note Only one battery system can be connected to a Solar Log device ...
Page 463: ...463 04 Heating rods ...
Page 470: ...470 05 Heating pumps ...
Page 478: ...478 06 Sensors ...
Page 488: ...488 07 Pyranometer ...
Page 495: ...495 08 Smart Plug components ...
Page 502: ...502 09 Power Charging Stations ...