34
ABB
4.5
ABB - Sunspec via RS485
Termination
Adressing
Interface
Switch
Yes
RS485
Selections available under „ABB: Sunspec“
Supported models (as of firmware 4.1.2):
•
TRIO-50.0-TL-OUTD, TRIO-50.0-TL-OUTD-US-480
•
TRIO-TM-50.0-400
•
TRIO-TM-60.0-480, TRIO-TM-60.0-480-US
Overview
•
Integrated interface.
•
Where to connect: RJ 45 socket, on the outside of the inverter‘s interface card.
•
2-pin wiring.
•
The communication address has to be assigned.
•
Installation steps:
•
Switch off the inverters and the Solar-Log™.
•
Connect the inverters to the Solar-Log™.
•
Connect the inverters to each other.
•
Set the communication address according to the inverter‘s instructions.
Connect the inverters to the Solar-Log™
The wiring is done using a
•
ready-made data cable (optional accessory; not supplied)
or
•
self-made RS485 data cable with RJ45 plug and terminal block connector.
Caution
Risk of damage to the unit!
The Solar-Log™ also has an RJ45 socket, which must never be connected to the RJ45 socket on the
inverter.
►
Only connect inverters via the RS485/422 Solar-Log™ interface(s).
Procedure
1. If you are making the cable yourself, connect the wires as shown in the following diagram:
Note
The RS485-2 interfaces have to be used in order to communicate with the Solar-Log™. Do not use the
RS481-1 interface. (Refer to the inverter‘s manual.)
Summary of Contents for Solar-Log
Page 1: ...1 Components Connection Manual V 4 2 3 Solar Log EN ...
Page 20: ...20 01 Inverter ...
Page 398: ...398 Appendix 113Appendix 113 1 SMA mixed wiring Fig SMA mixed wiring ...
Page 402: ...402 02 Meter ...
Page 444: ...444 03 Battery Systems ...
Page 456: ...456 sonnen Note Only one battery system can be connected to a Solar Log device ...
Page 463: ...463 04 Heating rods ...
Page 470: ...470 05 Heating pumps ...
Page 478: ...478 06 Sensors ...
Page 488: ...488 07 Pyranometer ...
Page 495: ...495 08 Smart Plug components ...
Page 502: ...502 09 Power Charging Stations ...