413
Solar-Log™ PRO
4.2
Solar-Log™ PRO380 Mod
Selections available under Solar-Log Pro
Overview
•
The communication address has to be assigned.
•
2-pin wiring.
•
Installation steps:
•
Switch off the meter and the Solar-Log™.
•
Connect the meter to the Solar-Log™.
Note
The communication address is set to 1 by default, but can be adjusted if several meters are connected
to one RS485 bus. Maximum of 32 meters per RS485 bus
Connect the meter to the Solar-Log™.
The wiring is done using a
•
self-made cable connection with a terminal block connector.
4.2.1
Connection diagram
according to circuit type 1000 (DIN 43856)
Input "L1, L2, L3"
Supply line input phase "L1, L2, L3"
Output "L1, L2, L3"
Supply line output phase "L1, L2, L3"
Terminal "N"
Neutral conductor connection "N"
Terminal 18, 19
S
o
pulse output "FOWARD" (terminal 18 = "+")
Terminal 20, 21
S
o
pulse output "REVERSE" (terminal 20 = "+")
Terminal 22, 23
ModBus connection terminal 22 -> A, 23 -> B
Terminal 24, 25
External tariff switching (230V AC)
Fig.: Pin assignment
Summary of Contents for Solar-Log
Page 1: ...1 Components Connection Manual V 4 2 3 Solar Log EN ...
Page 20: ...20 01 Inverter ...
Page 398: ...398 Appendix 113Appendix 113 1 SMA mixed wiring Fig SMA mixed wiring ...
Page 402: ...402 02 Meter ...
Page 444: ...444 03 Battery Systems ...
Page 456: ...456 sonnen Note Only one battery system can be connected to a Solar Log device ...
Page 463: ...463 04 Heating rods ...
Page 470: ...470 05 Heating pumps ...
Page 478: ...478 06 Sensors ...
Page 488: ...488 07 Pyranometer ...
Page 495: ...495 08 Smart Plug components ...
Page 502: ...502 09 Power Charging Stations ...