433
Janitza UMG 104 / UMG 604 / UMG 604-PRO (Utility Meter)
7.2 Janitza UMG 604 / UMG 604-PRO via Ethernet
Termination
Addressing
Interface
No
Yes
LAN
Overview
•
Integrated interface.
•
Connect using network cable (patch cable) and Ethernet router or switch.
•
A static IP address must be assigned.
•
Installation steps:
•
Switch off the Janitza device and the Solar-Log™.
•
Connect the Janitza device to the Solar-Log™.
Connect Janitza to the Solar-Log™
The wiring is done using a
•
network cable (patch cable/crossover cable) and the
•
Ethernet router or switch.
Assign the IP address for detection and communication:
IP addresses assignment according to manufacturer’s instructions. Both devices need to be in the same subnet
mask.
Detection via the Solar-Log™ WEB Interface
•
For detection on the Solar-Log™ , select the device class under the menu
Configuration | Device | Definition
| Interface
with the plus symbol and then select Janitza as the manufacturer. Confirm your selection with OK.
•
Save your selections and then start the Device Detection under
Configuration | Device | Detection
.
Detection from the Solar-Log 1200
•
When using the Solar-Log 1200, the detection can also be started from the display. Select the settings ►Start
►
Initial Configuration
►
Page 2 „Device“
►
Add and select the manufacturer Janitza from there. Save and
start the Device Detection.
Note
The meter operating modes via Ethernet are identical to those of the RS485 version.
Summary of Contents for Solar-Log
Page 1: ...1 Components Connection Manual V 4 2 3 Solar Log EN ...
Page 20: ...20 01 Inverter ...
Page 398: ...398 Appendix 113Appendix 113 1 SMA mixed wiring Fig SMA mixed wiring ...
Page 402: ...402 02 Meter ...
Page 444: ...444 03 Battery Systems ...
Page 456: ...456 sonnen Note Only one battery system can be connected to a Solar Log device ...
Page 463: ...463 04 Heating rods ...
Page 470: ...470 05 Heating pumps ...
Page 478: ...478 06 Sensors ...
Page 488: ...488 07 Pyranometer ...
Page 495: ...495 08 Smart Plug components ...
Page 502: ...502 09 Power Charging Stations ...