445
Kyocera Inverter/Battery System
1
Kyocera Inverter/Battery System
1.1
Kyocera Inverter/Battery System
Termination
Addressing
Interface
No
Yes
RS485
Selections available under Kyocera
Overview
•
Integrated interface.
•
Where to connect: Terminal strip under the cover on the bottom.
•
The communication address has to be assigned.
•
2-pin wiring.
•
Installation steps:
•
Switch off the inverters and Solar-Log™.
•
Connect inverters to the Solar-Log™.
•
Connect the inverters/battery systems to each other.
•
Assign the communication address according to the manufacturer‘s manual.
Connect the inverters to the Solar-Log™.
The wiring is done using a
•
self-made, shielded 4-wire data cable with a terminal block connector.
Procedure
1. Unscrew the side cover as shown in the inverter‘s instructions.
2. If you are making the cable yourself, connect the wires as shown in the following diagram:
Solar-Log™ terminal strip connector
Inverter terminal strip
Terminal
PIN
►
1 Data+
►
3 Data+
►
4 Data-
►
4 Data-
3. Screw the inverter cover on again.
4. Insert the terminal block connector into the Solar-Log™ RS485 socket.
Connect the inverters to each other.
•
Where to connect: Terminal strip under the cover on the bottom.
Summary of Contents for Solar-Log
Page 1: ...1 Components Connection Manual V 4 2 3 Solar Log EN ...
Page 20: ...20 01 Inverter ...
Page 398: ...398 Appendix 113Appendix 113 1 SMA mixed wiring Fig SMA mixed wiring ...
Page 402: ...402 02 Meter ...
Page 444: ...444 03 Battery Systems ...
Page 456: ...456 sonnen Note Only one battery system can be connected to a Solar Log device ...
Page 463: ...463 04 Heating rods ...
Page 470: ...470 05 Heating pumps ...
Page 478: ...478 06 Sensors ...
Page 488: ...488 07 Pyranometer ...
Page 495: ...495 08 Smart Plug components ...
Page 502: ...502 09 Power Charging Stations ...