448
Phonosolar
Procedure
1. Unscrew the cover according to the PhoneCube instructions.
2. If you are fabricating the cable yourself, connect the wires as shown in the following diagram.
Solar-Log™ terminal strip connector
PhonoCube Terminal Strip
Terminal
PIN
►
1 A/Data+
1 - Data+
►
4 B/Data-
2 - Data-
3. Screw the PhonoCube cover on again.
4. Insert the terminal block connector into the Solar-Log™ RS485 socket.
Connect the PhonoCubes to each other
•
Where to connect: Terminal strip under the cover on the backside.
Procedure
1. Unscrew the cover according to the PhoneCube instructions.
2. Connect the self-made RS-485 cable to the PhonoCube terminal block 1.
3. Connect the other end of the cable to the PhonoCube terminal block 2.
4. Connect additional PhonoCubes to each other in the same way.
5. Screw the inverter cover on again.
Allocate communication address
•
Recommendation: Continuous numbering from 1 to 247
•
Procedure: Start according to the PhonoCube instructions.
Note
Only one battery system can be connected to a Solar-Log™ device.
Summary of Contents for Solar-Log
Page 1: ...1 Components Connection Manual V 4 2 3 Solar Log EN ...
Page 20: ...20 01 Inverter ...
Page 398: ...398 Appendix 113Appendix 113 1 SMA mixed wiring Fig SMA mixed wiring ...
Page 402: ...402 02 Meter ...
Page 444: ...444 03 Battery Systems ...
Page 456: ...456 sonnen Note Only one battery system can be connected to a Solar Log device ...
Page 463: ...463 04 Heating rods ...
Page 470: ...470 05 Heating pumps ...
Page 478: ...478 06 Sensors ...
Page 488: ...488 07 Pyranometer ...
Page 495: ...495 08 Smart Plug components ...
Page 502: ...502 09 Power Charging Stations ...