479
Sensor Basic
1 Sensor Basic
Properties
•
Sensor element: Crystalline solar cell, 20 mm x 34 mm
•
Measurement range irradiance: 0 - 1400 W/m
2
•
Error of max. +/- 2 K at 25 °C cell temperature
•
Sensorelement: KTY83-110
•
Measurement range cell temperature: -25 – +75 °C
•
Error of max. 8 % (FSR) at vertical light beam and under standard test condition (STC)
•
Differential data communication
•
Cable prolongable up to 50 m (165 feet)
Sensor Case
Material
Powder-coated aluminum
Mounting Plate
3 mm powder-coated Aluminum with 4 x M8-drill holes
Drill Size (WxHxD)
138 mm x 38 mm x 64 mm (with mounting plate)
Weight
ca. 440 g
Protection Class
IP67
Ambient Temperature
-20 – +70 °C
Temperature Range
-25 – +85 °C
Relative Air Humidity
20 – 95 %
Electronics
Power Supply
8 – 28 Vdc, via RS485 Data Cable from Solar-Log™
Supply Current
Typical 10 mA
Communication Port
RS485
Protocol
Solar-Log™, 9600 Baud, 8N1
Connection Cable
•
4 pole, 3 m (10 feet), weather and uv resistant (LiY(St)
11 Y (4 x 0,14)
•
prolongable up to 50 m (165 feet)
Summary of Contents for Solar-Log
Page 1: ...1 Components Connection Manual V 4 2 3 Solar Log EN ...
Page 20: ...20 01 Inverter ...
Page 398: ...398 Appendix 113Appendix 113 1 SMA mixed wiring Fig SMA mixed wiring ...
Page 402: ...402 02 Meter ...
Page 444: ...444 03 Battery Systems ...
Page 456: ...456 sonnen Note Only one battery system can be connected to a Solar Log device ...
Page 463: ...463 04 Heating rods ...
Page 470: ...470 05 Heating pumps ...
Page 478: ...478 06 Sensors ...
Page 488: ...488 07 Pyranometer ...
Page 495: ...495 08 Smart Plug components ...
Page 502: ...502 09 Power Charging Stations ...