Rainwise - PVMet™-200 (Weather station)
3
Rainwise - PVMet™-200 (Weather station)
3.1
PVMet™-200 (Weather station)
Termination
Addressing
Interface
-*
No
RS485
Selections available under Sensor/Rainwise/PVMet200.
Supported by firmware 4.1.0 and higher.
Overview
•
Integrated interface.
•
Where to connect: Terminal strip on circuit board under the cover.
•
Communication address does not have to be assigned.
•
4-pin wiring.
•
Installation steps:
•
Switch of the PVMet™-200 and the Solar-Log™.
•
Connect the PVMet™-200 to the Solar-Log™.
Connect the PVMet™-200 to the Solar-Log™.
The wiring is done using a
•
self-made, shielded 4-wire data cable with a terminal block connector.
Procedure
1. If you are making the cable yourself, connect the wires as shown in the following diagram:
Solar-Log™ terminal strip connector
Terminal strip on circuit board
Terminal
PIN
►
1
►
RS485 A-
►
3
►
Ground/GND
►
4
►
RS485 B+
*Termination
:
Please contact Rainwise for information on termination.
Note
Only one PVMet™ -200 can be connected and visualized per Solar-Log™ device.
Summary of Contents for Solar-Log
Page 1: ...1 Components Connection Manual V 4 2 3 Solar Log EN ...
Page 20: ...20 01 Inverter ...
Page 398: ...398 Appendix 113Appendix 113 1 SMA mixed wiring Fig SMA mixed wiring ...
Page 402: ...402 02 Meter ...
Page 444: ...444 03 Battery Systems ...
Page 456: ...456 sonnen Note Only one battery system can be connected to a Solar Log device ...
Page 463: ...463 04 Heating rods ...
Page 470: ...470 05 Heating pumps ...
Page 478: ...478 06 Sensors ...
Page 488: ...488 07 Pyranometer ...
Page 495: ...495 08 Smart Plug components ...
Page 502: ...502 09 Power Charging Stations ...