ALPHA-SOL
8 ALPHA-SOL
8.1 ALPHA-SOL
Termination
Addressing
Interface
Switch
Yes
RS485
Overview
•
Interface not integrated; Retrofit RS485 interface card.
•
4-pin wiring.
•
Communication address must be allocated.
•
Installation steps:
•
Allocate communication address.
•
Switch off the inverters and Solar-Log™.
•
Install the RS485 interface in the inverter.
•
Connect inverters to the Solar-Log™.
•
Connect the inverters to each other.
Allocate communication address
•
Recommendation: Continuous numbering starting with 1.
•
Setting: Using the DIP switch on the interface card.
Before
installing the RS485 interface card:
►
Allocate the communication address using the 8 interface card DIP switches:
Example - Communication address 1:
On
Off
DIP switch
Example - Communication address 2:
On
Off
DIP switch