80
Chint Power
16.3
Chint Power Modbus (DO - DO/HE)
Termination
Addressing
Interface
No
Yes
RS485
Selection available under Chint Power: Modbus.
The following types are to be connected according to this diagram:
•
CPS SCA5KTL-DO
•
CPS SCA6KTL-DO
•
CPS SCA7KTL-DO
•
CPS SCA8KTL-DO
•
CPS SCA10KTL-DO
•
CPS SCA12KTL-DO
•
CPS SCA8KTL-DO/HE
•
CPS SCA10KTL-DO/HE
•
CPS SCA12KTL-DO/HE
Select the inverter Chint-Mod for the inverter detection.
Overview
•
Integrated interface.
•
Where to connect: RJ45 socket on the outside of the inverter.
•
2-pin wiring.
•
The communication addresses (1-247) have to be assigned.
•
Installation steps:
•
Switch off the inverters and Solar-Log™.
•
Connect inverters to the Solar-Log™.
•
Connect the inverters to each other.
•
Allocate communication address.
Caution
Risk of damage to the unit!
The Solar-Log™ also has an RJ45 socket, which must never be connected to the RJ45 socket on the
inverter.
►
Only connect inverters via the RS485/422 Solar-Log™ interface(s).
Connect inverters to the Solar-Log™
The wiring is done using a
•
self-made, shielded 2 wire data cable with a RJ45 socket and a terminal block connector.
Summary of Contents for Solar-Log
Page 1: ...1 Components Connection Manual V 4 2 3 Solar Log EN ...
Page 20: ...20 01 Inverter ...
Page 398: ...398 Appendix 113Appendix 113 1 SMA mixed wiring Fig SMA mixed wiring ...
Page 402: ...402 02 Meter ...
Page 444: ...444 03 Battery Systems ...
Page 456: ...456 sonnen Note Only one battery system can be connected to a Solar Log device ...
Page 463: ...463 04 Heating rods ...
Page 470: ...470 05 Heating pumps ...
Page 478: ...478 06 Sensors ...
Page 488: ...488 07 Pyranometer ...
Page 495: ...495 08 Smart Plug components ...
Page 502: ...502 09 Power Charging Stations ...