219
Platinum (formerly Diehl Ako)
61.2
Platinum H
Termination
Addressing
Interface
Yes
Yes
RS485
Select “Platinum: H-Serie” during the inverter detection
Overview
•
Integrated interface
•
Where to connect: Terminal strip inside the inverter
•
2-pin wiring
•
Communication address must be allocated
•
Installation steps
•
Switch off the inverters and Solar-Log™
•
Connect inverters to the Solar-Log™
•
Connect the inverters to each other
•
Configure the inverter’s communication interface
•
Allocate communication address
Connect inverters to the Solar-Log™
The wiring is done using a
•
self-made, shielded 2 wire data cable and terminal block connector.
Procedure
1. Connect wires as shown in the diagram below.
Solar-Log™ terminal strip connector
Inverter terminal strip
Terminal
Terminal
►
1
►
B (Data +)
►
4
►
A (Data -)
2. If no further inverter is connected, terminate the inverter according to the instructions for the inverter.
3. Close the inverter cover if no other inverters are to be connected.
4. Insert the terminal block connector into the Solar-Log™ RS485 socket.
Connect the inverters to each other
The inverters are connected together using
the RS485 interface. Refer to the manufacturer’s inverter manual for the details on how to setup the connection.
Allocate communication address
•
Recommendation: Continuous numbering starting with 1
•
Setting: Using the inverter operating display
•
Procedure: Start according to the inverter’s instructions
Summary of Contents for Solar-Log
Page 1: ...1 Components Connection Manual V 4 2 3 Solar Log EN ...
Page 20: ...20 01 Inverter ...
Page 398: ...398 Appendix 113Appendix 113 1 SMA mixed wiring Fig SMA mixed wiring ...
Page 402: ...402 02 Meter ...
Page 444: ...444 03 Battery Systems ...
Page 456: ...456 sonnen Note Only one battery system can be connected to a Solar Log device ...
Page 463: ...463 04 Heating rods ...
Page 470: ...470 05 Heating pumps ...
Page 478: ...478 06 Sensors ...
Page 488: ...488 07 Pyranometer ...
Page 495: ...495 08 Smart Plug components ...
Page 502: ...502 09 Power Charging Stations ...