382
Voltwerk
106
Voltwerk
106.1
Voltwerk (only Solar-Log 1000, 1900 and 2000)
Note
Voltwerk inverters can only be connected to the Solar-Log 1000, 1900 and 2000, as only this one has a
CAN interface.
The following description relates to inverters without transformers produced in or after 2007.
Termination
Addressing
Interface
Yes
No
CAN bus
Overview
•
CAN only to be used on Solar-Log 1000, 1900 and 2000 (CAN interface).
•
Integrated interface
•
Where to connect: CAN socket on the outside of the bottom of the inverter
•
Only use ready-made cable sets
Two different special cable sets must be ordered separately
-
Prefabricated cable set between the Solar-Log 1000, 1900 and 2000 and the first inverter, including cable
termination
-
Ready-made cable set with 5 pin Phoenix contact connection plug for connecting the inverters to each
other
The number of cables are required depends on the number of inverters
Maximum total cable length: 200 m
•
Communication address does not have to be assigned
•
Installation steps
•
Switch off the inverters and Solar-Log™
•
Connect inverters to the Solar-Log™
•
Connect the inverters to each other
PIN assignment:
Solar-Log™ terminal strip connector
Sensor / actuator connector 5-pin
Terminal
Pin
4 not used
1 not used
5 not used
2 not used
►
1
►
3
►
3
►
4
►
2
►
5
At Solarlog ™ set a 120
Ω
resistor between PIN 2 and 3
Summary of Contents for Solar-Log
Page 1: ...1 Components Connection Manual V 4 2 3 Solar Log EN ...
Page 20: ...20 01 Inverter ...
Page 398: ...398 Appendix 113Appendix 113 1 SMA mixed wiring Fig SMA mixed wiring ...
Page 402: ...402 02 Meter ...
Page 444: ...444 03 Battery Systems ...
Page 456: ...456 sonnen Note Only one battery system can be connected to a Solar Log device ...
Page 463: ...463 04 Heating rods ...
Page 470: ...470 05 Heating pumps ...
Page 478: ...478 06 Sensors ...
Page 488: ...488 07 Pyranometer ...
Page 495: ...495 08 Smart Plug components ...
Page 502: ...502 09 Power Charging Stations ...