90
Danfoss
20
Danfoss
20.1
Danfoss
Termination
Addressing
Interface
Connection plug
No
RS485
Overview
•
Integrated interface.
•
Where to connect: 2 RJ45 sockets on the right on the side cover.
•
Communication address does not have to be assigned.
•
4-pin wiring.
•
Installation steps:
•
Switch off the inverters and Solar-Log™.
•
Connect inverters to the Solar-Log™.
•
Connect the inverters to each other.
Connect inverters to the Solar-Log™
The wiring is done using a
•
ready-made RJ45 data cable (optional extra; not supplied)
or
•
self-made cable connection with RS485 data cable and terminal block connector.
Caution
The Master Mode has to be deactivated in the Pro series devices. See the manufacturer's manual for
more detailed instructions.
Procedure
1. Unscrew the side cover as shown in the inverter's instructions.
2. If you are making the cable yourself, connect the wires as shown in the following diagram:
Solar-Log™ terminal strip connector
RJ45 inverter
Terminal
PIN
►
1
►
6
►
3
►
1
►
3
►
2
►
4
►
3
Summary of Contents for Solar-Log
Page 1: ...1 Components Connection Manual V 4 2 3 Solar Log EN ...
Page 20: ...20 01 Inverter ...
Page 398: ...398 Appendix 113Appendix 113 1 SMA mixed wiring Fig SMA mixed wiring ...
Page 402: ...402 02 Meter ...
Page 444: ...444 03 Battery Systems ...
Page 456: ...456 sonnen Note Only one battery system can be connected to a Solar Log device ...
Page 463: ...463 04 Heating rods ...
Page 470: ...470 05 Heating pumps ...
Page 478: ...478 06 Sensors ...
Page 488: ...488 07 Pyranometer ...
Page 495: ...495 08 Smart Plug components ...
Page 502: ...502 09 Power Charging Stations ...