Chapter 3: Installation of the inverter
SolarEdge Installation Guide - MAN-01-00060-2.6
19
•
When installing inverters one above another, leave at least a space of 40 cm / 16 "between the
inverters.
When installing inverters side by side, follow the free space following specifications:
Single-phase UPS
Three-phase UPS
Pitches with an upper annual average temperature
below 25
VS
below 25
VS
20 cm / 8 "between the inverters
20 cm / 8 "between the
inverters
Pitches with an upper annual average temperature
above 25
VS
above 25
VS
40 cm / 16 "between the
inverters
•
Position the mounting bracket against the wall / pole and mark the location of punched holes (refer to
Appendix C: Mechanical Specifications
Dimensions of the inverter and the mounting bracket on page 68):
•
For type 1 - Ensure that the U-shaped notches are oriented upwards and the marking "up" is properly
oriented, as illustrated below:
Figure 6: Mounting with U-shaped notches face upwardly
•
For type 2 - Ensure that the flat portion of the support is downwardly as shown in Figure 8
•
Use at least two holes for the support. Additional holes can be used to secure the bracket. Identify holes
and how much will be used depending on the type and material of the mounting surface.
2
Drill the holes and mount the bracket. Check that the support is firmly attached to the surface of
2
Drill the holes and mount the bracket. Check that the support is firmly attached to the surface of
2
Drill the holes and mount the bracket. Check that the support is firmly attached to the surface of
mounting.
3
Hang the inverter on the support (Figure 7 and Figure 8), lift the inverter on the sides, or
3
Hang the inverter on the support (Figure 7 and Figure 8), lift the inverter on the sides, or
enter the inverter from the top and from the bottom to lift the UPS in its place
•
For type 1 - Use the screws on the top of the inverter as shown below. Leave the flat inverter against the
wall or pole.